California Exam Formula Conversion Sheet, Explained (T1-T4, D1-D4)
If you're sitting a California drinking water treatment (T) or distribution (D) exam, you don't have to memorize formulas. The State Water Board gives you its Exam Formula Conversion Sheet during the test. The current version was revised 4/30/2026.
That sounds like it makes the math easy. It doesn't, and here's why: the sheet gives you the formula but not the judgment. It won't tell you which of its dozens of lines a question wants, that your flow has to be in MG before you multiply, or that the "%" in a formula means divide by 100 first. That's where people lose points.
So this guide walks the sheet the way it's laid out, section by section. For each one I'll tell you what it's for, the trap I see people fall into, and a worked example using the sheet's own numbers (3.14, .785, 7.48, 8.34).
Get the real sheet first. Download it straight from the source: the State Water Board's Exam Formula Conversion Sheet (PDF). Print it and keep it next to you while you work through this page and the California practice tests. You want to know where everything sits on that sheet before test day, not hunt for it under a timer.
Key takeaways
- The sheet is the same one for treatment and distribution exams. The Board's page lists it under both.
- Most wrong answers come from units, not arithmetic. Flow goes in MG or MGD in every pounds formula.
- Anything in "%" gets divided by 100 before it goes in a formula. The sheet writes this as "(%/100)" and it means it.
- The sheet uses 3.14, .785, 7.48 and 8.34. Use the same numbers so your answer matches the choices.
- Know the four or five conversions you'll use constantly (694.4, 448.8, 2.31, 0.433, 7.48) so you're not looking them up every time.
What's on the sheet
The 2026 sheet is two landscape pages:
| Page | Sections |
|---|---|
| 1 | Units and conversion factors, area and volume, flow and velocity, pumping, electrical/SCADA, solutions, dilution and blending, chlorination, sedimentation, other |
| 2 | Chemical dosage calculations, filtration, C x T calculations |
The Board's page also still links older 2016 versions of the treatment and distribution conversion sheets. The 2026 "New Format" sheet is the current one. If you're unsure which one your exam uses, check your exam admission information or ask the Board's operator certification office.
Units and conversion factors
The left side of page 1 is a list of abbreviations (MGD, CFS, SLR, UFRV and so on) and a column of conversion factors. These are the ones you'll use over and over:
| Conversion | Value |
|---|---|
| 1 ft³ of water | 7.48 gal |
| 1 gal of water | 8.34 lb |
| 1 MGD | 694.4 gpm, or 1.55 cfs |
| 1 cfs | 448.8 gpm |
| 1 psi | 2.31 ft of water |
| 1 ft of water | 0.433 psi |
| 1 % | 10,000 mg/L |
| 1 mg/L | 1 ppm |
| 1 gpg (grain per gallon) | 17.1 mg/L |
| 1 acre | 43,560 ft² |
| 1 acre-foot | 325,851 gal |
| 1 CCF (hundred cubic feet) | 100 ft³, or 748 gal |
| 1 HP | 0.746 kW, or 33,000 ft-lb/min |
| 1 day | 24 hr, 1,440 min, 86,400 sec |
One detail worth noticing: the sheet says 1 ft³ of water weighs 62.3832 lb. Most textbooks round to 62.4. If a question hinges on it, use the sheet's number.
The bottom of that column has the temperature formulas:
°C = (°F - 32) / 1.8
°F = (°C x 1.8) + 32
Example: a flow conversion. A plant runs 2.5 MGD. What is that in gpm?
2.5 MGD x 694.4 = 1,736 gpm
Example: pressure and head. A storage tank's water level sits 115 ft above a gauge. What does the gauge read?
115 ft x 0.433 = 49.8 psi
And going the other way, 65 psi is 65 x 2.31 = 150.2 ft of head.
The trap: using 2.31 when you needed 0.433, or the reverse. Feet are the bigger number. If you're converting psi to feet and your answer got smaller, you used the wrong factor.
Example: hardness. A water tests at 12 gpg. In mg/L that's 12 x 17.1 = 205 mg/L.
Area and volume
Area of a circle = .785 x D²
Area of a rectangle = Length x Width
Area of a right triangle = (Base x Height) / 2
Circumference = 3.14 x D
Cylinder volume (gal) = .785 x D² x Height (or Length) x 7.48
Rectangular basin (gal) = Length x Width x Height x 7.48
Example: tank volume (T and D). A round storage tank is 40 ft across and 30 ft tall. How many gallons does it hold full?
.785 x 40² x 30 x 7.48
= .785 x 1,600 x 30 x 7.48
= 281,846 gal
Example: pipe volume (D exams love this). How many gallons are in 1,200 ft of 8-inch main?
D = 8 in / 12 = 0.667 ft
.785 x 0.667² x 1,200 x 7.48 = 3,132 gal
The trap: leaving the diameter in inches. Every dimension in these formulas is in feet. Divide inches by 12 first, and do it before you square.
Flow and velocity
Q (ft³/sec) = A (ft²) x V (ft/sec)
V = Q / A
A = Q / V
Example: velocity in a main. A 12-inch main carries 900 gpm. How fast is the water moving?
Q = 900 gpm / 448.8 = 2.005 cfs
A = .785 x 1² = .785 ft²
V = 2.005 / .785 = 2.55 ft/sec
The trap: plugging gpm straight into Q = A x V. The formula only works in cubic feet per second. Convert first.
Pumping
The pumping block is one family of formulas built on the number 3960:
Water HP = (GPM x Head) / 3960
Brake HP = (GPM x Head) / (3960 x Pump Eff/100)
Motor HP = (GPM x Head) / (3960 x Pump Eff/100 x Motor Eff/100)
Wire-to-water efficiency (%) = (Pump Eff/100) x (Motor Eff/100)
Cost ($) = HP x .746 x Operating hours x $/kWh
Specific capacity (gpm/ft) = Well yield (gpm) / Drawdown (ft)
Example: horsepower. A pump moves 750 gpm against 140 ft of total head. The pump is 78% efficient and the motor is 90% efficient.
Water HP = (750 x 140) / 3960 = 26.5 HP
Brake HP = 26.5 / 0.78 = 34.0 HP
Motor HP = 34.0 / 0.90 = 37.8 HP
Wire-to-water efficiency = 0.78 x 0.90 = 70.2%
Water HP is always the smallest number and motor HP the largest. If yours come out the other way around, you multiplied by the efficiency instead of dividing.
Example: power cost. That 37.8 HP motor runs around the clock for a 30-day month (720 hours) at $0.22 per kWh.
37.8 x .746 x 720 x 0.22 = $4,467
Example: specific capacity. A well pumps 450 gpm with 30 ft of drawdown. Specific capacity is 450 / 30 = 15 gpm per foot. Drawdown is the pumping level minus the static level, so if the question gives you both levels, subtract first.
Electrical and SCADA: the 4-20 mA formula
Process value = (Live signal (mA) - 4 mA) x Process range / 16 mA
A transmitter sends 4 mA at the bottom of its range and 20 mA at the top. The 16 is the span between them.
Example. A tank level transmitter is ranged 0 to 40 ft and reads 13 mA. What's the level?
(13 - 4) x 40 / 16 = 22.5 ft
The trap: forgetting to subtract the 4. 13 / 20 x 40 gives 26 ft, which is wrong and is very often one of the answer choices. If the range doesn't start at zero, add the bottom of the range back on at the end.
Solutions, dilution and blending
Specific gravity = Chemical weight (lb/gal) / 8.34
Chemical in solution (%) = Dry chemical (lb) x 100 / Total solution weight (lb)
Chemical (lb) = SG x 8.34 x Solution (gal) x Solution (%/100)
C1 x V1 = C2 x V2
(C1 x V1) + (C2 x V2) = C3 x V3
Example: specific gravity. A chemical weighs 11.1 lb/gal. Its SG is 11.1 / 8.34 = 1.33.
Example: dilution (C1V1 = C2V2). You need 5 gallons of 1% chlorine solution and you have 12.5% hypochlorite. How much hypo do you start with?
12.5 x V1 = 1 x 5
V1 = 0.4 gal of 12.5% hypo, topped up to 5 gal with water
Example: blending two wells. Well A pumps 600 gpm at 14 mg/L nitrate. Well B pumps 900 gpm at 4 mg/L. What's the blended concentration?
(14 x 600) + (4 x 900) = C3 x 1,500
8,400 + 3,600 = C3 x 1,500
C3 = 8.0 mg/L
The trap: averaging the two concentrations (9 mg/L). The bigger well pulls the blend toward its number, which is the whole point of the formula.
Chlorination
Dosage (mg/L) = Demand (mg/L) + Residual (mg/L)
Gas (lb) = MG x mg/L x 8.34
HTH solid (lb) = (MG x mg/L x 8.34) / (Strength %/100)
Liquid (gal) = (MG x mg/L x 8.34) / (Strength %/100 x Chemical weight lb/gal)
Example: gas feed. A plant treats 3.5 MGD at a 2.8 mg/L chlorine dose. How many pounds per day?
3.5 x 2.8 x 8.34 = 81.7 lb/day
Example: demand plus residual. Chlorine demand is 1.9 mg/L and you want 0.6 mg/L left over. The dose is 1.9 + 0.6 = 2.5 mg/L. At 1.8 MGD that's 1.8 x 2.5 x 8.34 = 37.5 lb/day of gas.
Example: disinfecting a new main with HTH (D exams). You need 50 mg/L in the 3,132 gal of 8-inch main from earlier, using 65% HTH.
MG = 3,132 / 1,000,000 = 0.003132
(0.003132 x 50 x 8.34) / 0.65 = 2.0 lb of HTH
Example: liquid hypochlorite. A 0.75 MGD plant doses 3.0 mg/L using 12.5% hypo that weighs 10.0 lb/gal.
(0.75 x 3.0 x 8.34) / (0.125 x 10.0) = 15.0 gal/day
The traps: the gallons in a pipe or tank have to become million gallons (divide by 1,000,000) before they go in. And the 65% or 12.5% has to become 0.65 or 0.125. Skip either step and your answer will be off by a huge factor, which the wrong answer choices are built to catch.
Sedimentation
Detention time = Volume (gal) / Flow (gpm)
Surface loading rate (gpd/ft²) = Total flow (gpd) / Surface area (ft²)
Weir overflow rate (gpd/ft) = Flow (gpd) / Weir length (ft)
Example: detention time. A basin is 80 ft long, 20 ft wide and 12 ft deep, and the plant runs 1.2 MGD.
Volume = 80 x 20 x 12 x 7.48 = 143,616 gal
Flow = 1.2 x 694.4 = 833.3 gpm
DT = 143,616 / 833.3 = 172 min, or about 2.9 hr
Example: surface loading and weir overflow. A circular clarifier is 60 ft across and treats 2.5 MGD, with a weir around the full edge.
Area = .785 x 60² = 2,826 ft²
SLR = 2,500,000 / 2,826 = 885 gpd/ft²
Weir length = 3.14 x 60 = 188.4 ft
WOR = 2,500,000 / 188.4 = 13,270 gpd/ft
The trap: detention time wants volume over flow in matching units. Gallons over gpm gives minutes; gallons over gpd gives days. Pick the pair that lands in the units the question asks for.
Chemical dosage calculations (page 2)
Page 2 repeats the pounds formula and adds two versions you'll see on higher-grade exams:
ppm or mg/L = lb / (MG x 8.34)
ppm or mg/L = (gallons x % purity x lb/gal) / (MG x 8.34)
Liquid (gal) = (MG x mg/L x 8.34) / (Commercial purity/100 x Ion purity/100 x lb/gal)
The first one is just the pounds formula turned around: you know how much you fed and want the dose.
The "ion purity" version is for chemicals where only part of the product does the work. Fluoride is the classic example: fluorosilicic acid is sold as a 23% solution, and only about 79.2% of that is actually fluoride ion.
Example: fluoride feed (T3 and up). A 1.5 MGD plant needs to add 0.5 mg/L of fluoride using 23% fluorosilicic acid (79.2% fluoride ion, 10.5 lb/gal).
(1.5 x 0.5 x 8.34) / (0.23 x 0.792 x 10.5)
= 6.255 / 1.913
= 3.27 gal/day
The sheet's "Other" block on page 1 also has a feed pump conversion, mL/min to gallons per day:
gal/day = (Feed mL/min x 1,440) / (1,000 x 3.785)
A pump set at 125 mL/min feeds (125 x 1,440) / 3,785 = 47.6 gal/day.
Filtration (page 2)
Filtration rate (gpm/ft²) = Flow rate (gpm) / Filter area (ft²)
Backwash rate (gpm/ft²) = Flow rate (gpm) / Filter area (ft²)
Backwash pumping rate (gpm) = Filter area x Backwash rate
Backwash volume (gal) = Filter area x Backwash rate x Time (min)
Rate of rise (in/min) = Backwash rate x 12 / 7.48
UFRV (gal/ft²) = Volume produced in a filter run (gal) / Filter area (ft²)
Daily filter production (gpd) = Filter area x gpm/ft² x 1,440
Example: one filter, start to finish. A filter is 20 ft by 25 ft and runs at 1,250 gpm. It's backwashed at 15 gpm/ft² for 12 minutes and produced 3.6 MG over its last run.
Area = 20 x 25 = 500 ft²
Filtration rate = 1,250 / 500 = 2.5 gpm/ft²
Backwash pumping rate = 500 x 15 = 7,500 gpm
Backwash volume = 500 x 15 x 12 = 90,000 gal
Rate of rise = 15 x 12 / 7.48 = 24.1 in/min
UFRV = 3,600,000 / 500 = 7,200 gal/ft²
Daily production = 500 x 2.5 x 1,440 = 1,800,000 gpd
The trap: filter questions mix rates (gpm/ft²) and totals (gpm, gallons). Before you calculate, write down whether the question wants a rate per square foot or a total for the whole filter.
C x T calculations (page 2)
C x T = Chlorine residual (mg/L) x Time (min)
C x T calculated = T10 (min) x Chlorine residual (mg/L)
Inactivation ratio = Actual C x T / Table "E" C x T
Time (min) = C x T / Chlorine residual
Chlorine residual = C x T / Time
Log removal = Log(1.0 - %Removal/100) x (-1)
T10 is the time it takes 10% of the water to get through the contact basin, which is shorter than the theoretical detention time because water short-circuits. "Table E" refers to the required C x T values for the temperature and pH you're running, and an exam question will give you the number you need.
Example: inactivation ratio. Your residual is 1.2 mg/L and T10 is 28 minutes. The table requires a C x T of 26.
Actual C x T = 1.2 x 28 = 33.6
Inactivation ratio = 33.6 / 26 = 1.29
A ratio of 1.0 or more means you met the requirement. Below 1.0 means you didn't.
Example: log removal. A process removes 99.9% of something. How many logs is that?
1.0 - 0.999 = 0.001
Log(0.001) = -3
-3 x (-1) = 3-log removal
Handy to just know: 90% is 1-log, 99% is 2-log, 99.9% is 3-log, 99.99% is 4-log.
The trap: using theoretical detention time instead of T10. If the question gives you a T10 or a baffling factor, the plain volume-over-flow time is the wrong answer. My CT calculations guide goes deeper on this.
The rest of the "Other" block
A few short formulas round out page 1. They're quick points if you know where they are:
Removal (%) = (In - Out) / In x 100
Slope (%) = Rise / Distance x 100
Gal/capita/day = GPD / Population
lb force = PSI x Area (in²)
Cost/day ($) = lb/day x Cost/lb ($)
Example: removal. Iron goes from 0.85 mg/L in to 0.05 mg/L out: (0.85 - 0.05) / 0.85 x 100 = 94.1% removal.
Example: per-capita use. A system serving 14,500 people produces 2.1 MGD: 2,100,000 / 14,500 = 145 gallons per person per day.
Example: force on a flange. 30 psi pushing on an 8-inch blind flange: area = .785 x 8² = 50.24 in², so force = 30 x 50.24 = 1,507 lb. Note this one works in inches, because psi is pounds per square inch. It's the one place on the sheet you don't convert to feet.
How the sheet maps to your grade
Any grade can draw on any part of the sheet, but as a rough guide, here's where the weight tends to sit as you move up:
- T1 and D1: unit conversions, area and volume, pressure and head, the basic pounds formula, demand plus residual.
- T2 and D2: detention time, velocity, HTH and liquid hypo, dilution, pump horsepower.
- T3, T4, D3 and D4: filtration and backwash, C x T and inactivation ratio, log removal, blending, fluoride and ion purity, 4-20 mA, power cost.
How to practice with the sheet
- Print the official sheet and keep it next to you every time you study math. You want to know where things are on it without searching.
- Rework each example above using only the sheet, without looking at my steps.
- Take the California practice tests for your grade with the sheet in front of you, the way you'll sit the real exam.
- For more math reps, the operator math practice test and the chemical dosage calculator show the pounds formula with your own numbers.
If math is the part that worries you most, my Water Operator Math course works every one of these formula types by hand, step by step.
This guide is an independent study aid and isn't affiliated with the State Water Resources Control Board. Always use the sheet the Board provides on exam day, and confirm current exam details with the Board.